This is a day of PM2.5 readings from my home, recorded by Aura AQ. For much of the night, the line sits near the bottom of the chart. The first spikes appear in the morning. From 09:30 to 12:00, it settles down again: I'm out at the gym. Soon after I return, the line shoots up. In the evening, the spikes keep coming. The highest five-minute average reaches 722 µg/m³.

I associate those spikes with my vaping. The monitor sits in my office, about 2–3 metres from where I work and vape. It seems the best thing I did for the air in my office that day was go to the gym.
But how much is 722? Why can the room look clear while the reading climbs? And when does opening a window help? A few everyday examples make the numbers easier to understand.
The short answer: A PM2.5 reading estimates the mass of very small particles in the air. Cooking, vaping, smoke and candles can add them indoors. Cleaning, humidifiers and outdoor air can affect the reading too. When it rises, reduce the source and use extraction where you can. Open a window if the air outside is cleaner. Then watch how long the reading takes to return to its usual level. EPA's indoor particle guidance
What PM2.5 means in plain English
PM stands for particulate matter: tiny solid particles and liquid droplets suspended in air. The “2.5” refers to size, roughly particles 2.5 micrometres across or smaller. A micrometre is one thousandth of a millimetre. EPA's explanation of particle sizes
To picture that, think of a human hair. An average hair is about 70 micrometres thick, roughly 30 times the width of a particle at the upper end of PM2.5. EPA You could fit 400 particles that are 2.5 micrometres wide side by side along a single millimetre on a ruler.

That helps explain why a monitor can register a rise above a frying pan before you see smoke. Individual particles this small are invisible to the naked eye.
The dust you can see on a shelf is often much larger. Wiping the shelf does not tell you how much fine particulate matter remains in the air. There is a separate guide to PM1, PM2.5 and the other particle readings. Health Canada
What µg/m³ means
The units beside the number, µg/m³, mean micrograms per cubic metre. A microgram is a millionth of a gram. SEN6x datasheet
Imagine a room 4 metres by 4 metres, with a ceiling 2.5 metres high. It contains 40 cubic metres of air. Suppose the monitor reads 15 µg/m³ and the air is evenly mixed. That would mean 600 micrograms of particles in all that air, or 0.6 milligrams. Less than a milligram in the whole room. These are example numbers, not measurements from my office.
Tiny as that mass sounds, particles this small can travel deep into the lungs when you breathe them in. EPA
The number also leaves out something important: what the particles are made of. Oily droplets from a frying pan, candle soot and vape aerosol can all raise the same PM2.5 reading. The monitor cannot identify them from that number. EPA
Where indoor particles come from
A rise often has an identifiable source. These are common examples:
- Dinner in a frying pan. Frying, grilling and toasting can release particles. Burning the food adds more. An induction hob can produce a rise too, because heating the food and oil releases particles even without a gas flame. EPA's guide to indoor sources, research comparing gas and induction cooking
- Vaping and cigarettes. An electronic cigarette turns liquid into an aerosol of tiny droplets and particles. Some of that aerosol enters the room when you exhale. My graph is an example of the changes I see when I vape. EPA's explanation of e-cigarette aerosol
- Candles, incense and some heaters. Health Canada
- Cleaning. Sweeping and vacuuming can disturb settled dust. Sprays add droplets of the cleaning product. Health Canada
- An ultrasonic humidifier. It puts water into the air along with dissolved minerals. As the water evaporates, mineral particles can remain airborne. Sain and colleagues
- Outdoor air. Traffic pollution, smoke from a neighbour's wood stove and wildfire smoke can enter through windows, ventilation systems and gaps in the building. Health Canada
There is a less obvious source too. In a controlled experiment, compounds from a fragranced cleaning product reacted with ozone in the air and formed new particles. Those were specific test conditions, so the result does not apply to every cleaning routine. But it shows that particles can form in the air from some of the compounds that give a product its scent. Rosales and colleagues

Why exposure time matters
Fine particles can reach deep into the lungs and affect the respiratory and cardiovascular systems. People with heart or lung conditions, children and older adults can be more vulnerable. EPA's health guidance
You may not notice the pollution as it happens. Air can feel fresh even when the reading is high. Your nose and the way you feel are poor substitutes for a measurement. EPA's explanation of exposure
Researchers study both pollution over recent days and the air people breathe over many years. Liu and colleagues, 2019, ELAPSE study, 2021 These are population studies. They cannot tell me how much harm one evening caused me personally.
A simple example shows why duration matters. The following numbers are invented to explain the calculation. They are not Aura measurements.
Two flats, one day:
- Flat A. Someone fries burgers for half an hour, and the reading stays at 100 µg/m³. For the other 23.5 hours, it is 5 µg/m³.
- Flat B. The windows face a busy road. The reading stays at 20 µg/m³ all day, with no spikes.
Flat A's peak is five times higher. But its daily average is about 7 µg/m³, while Flat B's is 20 µg/m³.
For Flat A, the calculation is (100 × 0.5 + 5 × 23.5) ÷ 24 ≈ 7.
The steady level in Flat B deserves attention even though it makes a less dramatic graph.
That calculation does not establish that half an hour beside the frying pan is harmless. Someone leaning over it may breathe a more concentrated plume than a monitor across the room records. The monitor samples the air at its own position; it cannot measure what reached your lungs. Research on room measurements and personal exposure, EPA
My monitor is about 2–3 metres from where I vape, so it is close to the source. Keep that in mind when looking at the spikes. I did not measure what was happening in the other rooms.
What the WHO numbers mean
In 2021, the World Health Organization recommended two PM2.5 guideline levels to protect health:
| WHO guideline level | Averaging period |
|---|---|
| 15 µg/m³ | 24-hour mean |
| 5 µg/m³ | Annual mean |
The important word is mean, or average.
WHO defines the daily guideline using the 99th percentile of a year's daily averages: a measure near the upper end of those daily values. One day cannot tell us whether a whole year meets that recommendation. WHO guideline table, WHO's explanation
The guidelines apply both outdoors and indoors. They do not tell you how many minutes you can safely spend beside a smoking pan. WHO
Can I compare my 722 with the WHO guideline?
The averaging periods are different. My 722 µg/m³ is an average over five minutes; WHO's 15 µg/m³ concerns a whole day. Comparing them would be like comparing your speed while overtaking with your average speed for the entire journey.
I can calculate a daily average, though. Aura Link stores history in five-minute intervals, and all 288 intervals are present for 12 November. The results are:
| 12 November, my office | PM2.5, µg/m³ |
|---|---|
| Median of five-minute averages | 4.6 |
| Daily average | 38.9 |
| WHO 24-hour guideline level | 15 |
The median is the middle of the five-minute averages, with half below it and half above. The daily average is much higher because the spikes pull it up. You can see that in the opening graph: the line spends much of the day below the dashed daily average.
In Flat A, one short peak produced a daily average of about 7. My graph has many spikes across the day, especially in the evening. Together, they raise the daily average to 38.9. Calculation and data checks
That is above the WHO daily guideline value, with the averaging periods now matched. It remains a comparison with a home monitor's readings. The window was slightly open that day, the monitor was close to where I vaped, and its calibration for vape aerosol has not been checked. The firmware also caps the highest readings, as I explain below. The average describes the saved readings; I cannot use it to calculate my dose or judge the whole year.
Why a weather app might show a different number
A weather app may show an Air Quality Index, or AQI, rather than µg/m³. AQI is a score on a separate scale. A score of “50” and a concentration of “50 µg/m³” mean different things. Compare numbers with the same units and averaging periods. AirNow
How the sensor detects particles you cannot see
You have probably seen dust light up in a sunbeam coming through a window. An optical particle sensor uses a similar idea. It draws air through a small chamber, shines a light into it and detects the light scattered by particles. Software uses that signal to estimate their mass. Sensirion's explanation of optical particle sensing

“Estimate” matters here. The sensor converts scattered light into a mass estimate using assumptions about the particles. Vape droplets and humidifier mist can scatter light differently from ordinary dust, so their readings may have a different error.
Researchers have tested this with e-cigarette aerosol and other monitors. The correction needed depended on both the instrument and the aerosol. They did not test my Aura AQ, so I cannot borrow a correction factor from that study for my graph. The rise to 722 shows a strong response to the event; the exact particle mass is less certain. Original e-cigarette aerosol measurement study
Think of two alarm clocks that agree with each other but both run five minutes slow. Two identical monitors can agree and share a similar error too. The sensor manufacturer distinguishes agreement between units, called precision, from closeness to a reference measurement, called accuracy. Sensirion's specification statement
There is a blind spot at the small end. In Aura AQ builds with a SEN66 sensor, the specified PM2.5 size range starts at about 0.3 micrometres. Ultrafine particles are smaller than that range and need specialised measurement equipment. A low PM2.5 reading cannot rule them out. SEN6x datasheet, section 1.2
There is a ceiling at the other end too. Sensirion specifies the sensor's mass-concentration performance over 0–1000 µg/m³. My Aura AQ firmware caps saved PM2.5 readings at 999 µg/m³. These are separate limits: one belongs to the sensor specification, the other to the device software. SEN6x datasheet, section 1.2, recording and firmware notes
In this recording, individual readings reached 999 in 34 of the 288 five-minute intervals. If the sensor reported more than 999, the stored value would still be 999. The record therefore cannot tell me how far the highest sensor readings went beyond that ceiling, or what the true mass concentration was. Recording notes
A humidifier beside the monitor
You switch on an ultrasonic humidifier and PM2.5 jumps. Two effects may be involved.
The humidifier can put minerals from the water into the air as real particles. The water's mineral content affects this. Sain and colleagues
Mist droplets and particles that absorb moisture can also scatter light differently, changing the sensor's estimate. Jayaratne and colleagues
Keep the monitor away from the mist, use low-mineral water and clean the humidifier according to its instructions. That follows EPA's guidance. Ordinary drinking water may still contain minerals. EPA's humidifier guidance
For routine room measurements, keep the monitor away from the hob, steam and direct air currents. Leave it in the same place when comparing days. There is more detail in the monitor placement guide.
What to do when PM2.5 rises
- Reduce the source where you can. Avoid burning food, overheating oil or leaving crumbs on hot surfaces. If the rise comes from vaping indoors, keeping that source out of the room is the most direct change to make. EPA's indoor sources guide, EPA's e-cigarette aerosol guidance
- Capture cooking emissions near the pan. Switch on the cooker hood when you start cooking, preferably one that vents outdoors. A hood generally captures emissions better from the back of the hob than from the front. EPA advises leaving the hood running for another 10–20 minutes after cooking; the room may take longer to clear. EPA, Lunden and colleagues' cooker-hood study
- Check outdoor air before opening a window. Cleaner outdoor air can dilute indoor particles. Smoke or smog outside can add more. Health Canada
- Match the air cleaner to the room. Look at CADR, the clean air delivery rate: how much cleaned air it supplies per unit of time. A larger room needs a higher CADR, at the fan speed you will use. “HEPA” alone does not tell you how well the unit will clean your room. Give it space for airflow and replace the filter when needed. EPA's guide to air cleaners
- Look at the graph afterwards. How long did it take to return to its usual level? Note what you changed: the window, extraction or air cleaner. Those notes help explain the curve.
Particle filters in air cleaners and recirculating cooker hoods capture particles. Gas removal needs different treatment, and a particle filter does not remove CO₂. A recirculating hood also returns air to the same room, so it works differently from extraction to the outdoors. If CO₂ is rising, check ventilation. Cooking and recirculating-hood study, EPA on particles and gases
A particle monitor cannot replace a smoke alarm or a carbon monoxide alarm. Those devices have separate jobs. EPA's guidance on home monitors
If unexplained high readings keep returning, check the monitor's placement and condition, then look for sources and assess ventilation. Unusual dust, such as construction or workshop emissions, may need professional assessment.
Try it with your next dinner
An ordinary dinner can tell you something useful about your home.
- Leave the monitor in one place and cook as you normally would, with extraction.
- Note when cooking starts and ends, whether the hood is running and whether a window is open.
- Look at the level before cooking, the size of the rise and how long it takes to return to the usual range.
- On another day, cook a similar meal and change one thing, such as switching on the hood earlier. Compare the curves.
Different food, a hotter pan or a windy day can change the result too. Treat this as a home observation, with those differences in mind. It can help you find changes worth keeping.
What my graph showed me
The monitor cannot tell me how much harm each puff causes or replace medical advice. It does show how the particle reading changes in the room where I work. Looking at this day, I think it's time I quit this stuff.
Sources and further reading
The links beside each section lead to official guidance, manufacturer documentation or original research. Good starting points are the WHO's 2021 guidelines, EPA's overview of indoor particles, Health Canada's practical guidance and the SEN6x datasheet. The research and recording were checked on 13 November 2026; this English adaptation and the firmware-limit source check were completed on 14 November 2026.
About the recording and the daily average
The record covers 12 November 2026, 00:00–24:00, Europe/London. All 288 five-minute intervals contain PM2.5 summary data. The monitor was in my office, 2–3 metres from where I work and vape. I was at the gym from 09:30 to 12:00; the window was slightly open.
The daily average of 38.899 µg/m³ gives each five-minute mean the same weight. Weighting by the number of readings instead gives 38.842 µg/m³. The median of the five-minute means is 4.646619 µg/m³. Complete five-minute coverage does not establish uninterrupted sampling every second.
The highest five-minute mean, 722.0416 µg/m³, belongs to 18:15–18:20. Saved individual values reached 999 in 34 intervals. Aura AQ firmware caps this channel at 999, so these summaries cannot reconstruct higher readings before that cap. This source-code limit was checked on 14 November 2026; calibration for vape aerosol remains unverified.